Contact Us

Analytical Testing

Tensile Testing

Tensile Testing

Nexolve can perform measurement of many different tensile properties over the temperature range from --135 °C – 180 °C using an Instron model 5569 two column test frame with environmental chamber and load cells up to 1kN. Testing can be performed in accordance with ASTM standards D638, D882, D3528, D1002, D1938, to your specifications, or we can custom tailor a method to suit your product or testing needs.

Differential Scanning Calorimetry Measurements

Differential Scanning Calorimetry Measurements

NeXolve can perform measurement of glass transition temperature and melt temperatures in the temperature range from -50 °C – 725 °C using a TA Instruments Q200 modulated differential scanning calorimeter. Testing can be performed in accordance with ASTM standards D7426, D3418, E1356, to your specifications, or we can custom tailor a method to suit your product or testing needs.

Thermomechanical Analyzer Measurements

Thermomechanical Analyzer Measurements

NeXolve can perform measurement of coefficient of thermal expansion, creep, and glass transition temperature in the temperature range from -150 °C – 1000 °C using dynamic or modulated TMA modes using a TA Instruments Q400 Thermomechanical Analyzer. Probe configurations include expansion, macro expansion, penetration, and film/fiber probes for testing samples of many different configurations.

UV-Vis-NIR Spectroscopic Measurements

UV-Vis-NIR Spectroscopic Measurements

NeXolve can perform ultraviolet, visible, and near infrared transmission, reflection, and absorption measurements using a Perkin Elmer Lambda 950 UV/Vis/NIR spectrometer coupled with a spectralon coated integrating sphere.

Fourier Transform Infrared Spectroscopic Measurements

Fourier Transform Infrared Spectroscopic Measurements

NeXolve can perform infrared (IR) transmission, reflection, and absorption measurements using a Bruker Tensor 27 infrared spectrometer coupled with a gold coated integrating sphere.

Infrared Property Measurements

Infrared Property Measurements

NeXolve can perform measurement of IR reflectance and emittance using an AZ Technology Temp 2000A Emissometer/reflectometer.

Electrical Property Measurements

Electrical Property Measurements

NeXolve can perform measurement of surface or volume resistivity of materials in the 1 – 1.0 x 1012 Ohms range. Measurements are performed to ASTM D257 specifications, to your specifications, or we can custom tailor a method to suit your product or testing needs.

Surface Profilometry Measurements

Surface Profilometry Measurements

Nexolve can perform many different surface profilometry measurements using a Bruker Dektak 150 Surface Profiler with automated sample stage. 

Analytical Testing Price List

Analytical Testing Price List

NeXolve Analytical Price List